Accuracy:

  • ≤0.2% or 0.2K

temperature range:

  • -270~+1820℃ (set according to sensor measurement capability)

Options:

  • Industrial
  • Temperature Transmitter
Enviar Consulta
Model No. : GTM
Brand Name :
Warranty : 12 Months
Brand Name : Gaimc
Model Number : Gtm101
Product Name : Gtm102 Universal Input 4-20ma Output Head Mounted Temp Transmitter
Configuration mode : Slide Switch + Pc Programmable
Input : K, S, R, B, N, E, J, T Type Thermocouple
Temperature Range : -270~+1820℃
Accuracy : ≤0.2% Or 0.2k
Output : 4-20ma (Two-Wire)
Alarm : Decrease To ≤3.6ma Or Increase To ≥21.5ma
Range setting : Slide Switch /Pc Program
Mode : Standard Type /With Calibration Report
power : 18~35vdc
place of origin : China
Place of Origin : Shaanxi, China
más
3yrs

Xian, Shaanxi, China

Visite la tienda
  • proveedor de oro
  • Certificación de plataforma

Descripción del Producto

Transmisor de temperatura inteligente GTM que puede establecer el rango de medición a través del interruptor de dial. Puede recibir resistencia térmica pt100 (dos cables, tres cables, cuatro cables), señal de termopar y linealizar la señal de entrada, enviar la señal estándar de 4 ... 20 mA (sistema de dos cables) y transmitirla a DCS , PLC y otros equipos de control del sistema. Al mismo tiempo, se puede utilizar con el programador portátil HART o el software de programación de PC para programar la configuración del transmisor de temperatura.El producto tiene un diseño de estructura compacta, fácil instalación, alta precisión, buena estabilidad a largo plazo, protección contra rayos y resistencia a la electricidad. interferencia transitoria rápida (grupo de pulsos) y alta confiabilidad general. Es ampliamente utilizado en la medición de parámetros de temperatura en diversos procesos industriales y de control.

Descripción transmisor de temperatura pt100

Transmisor de temperatura montado en el cabezal de salida de 4-20 mA de entrada universal GTM102

Mostrar detalle

Transmisor de temperatura montado en el cabezal de salida de 4-20 mA de entrada universal GTM102

Transmisor de temperatura montado en cabezal de salida de 4-20 mA de entrada universal GTM102

Transmisor de temperatura montado en el cabezal de salida de 4-20 mA de entrada universal GTM102

Transmisor de temperatura montado en el cabezal de salida de 4-20 mA de entrada universal GTM102

Montaje en carril DIN

Transmisor de temperatura montado en cabezal de salida de 4-20 mA de entrada universal GTM102

Transmisor de temperatura montado en el cabezal de salida de 4-20 mA de entrada universal GTM102


Especificación


Model GTM
Input signal Thermal resistance(RTD):Pt100,Pt1000,Cu50
Thermocouple(TC):K,S,R,B,N,E,J,T
 Temperature range  -270~+1820℃(set according to sensor measurement capability)
 Conversion accuracy  ≤0.2% or 0.2K
 Output signal  4-20 mA(two-wire),HART
 Alarm  When the sensor fails (open circuit or short circuit), the output drops to ≤3.6mA or the output rises to ≥21.5mA
 Maximum load
(Note 1)
 (V power- 9 V)/0.025A (output current)
Limit current ≤25mA
Power supply voltage (Note 2)  9...30VDC
Response time 1S
Lightning protection (Note 3) ±4000V(≤5 times)
 Anti-pulse group
(Note 4)
 ±4000V
 Anti-radio frequency interference  >10V/m(80MHz~1000MHz)
 Ambient temperature  -40~85℃
 Temperature drift  0.008%FS/1℃
 Long-term stability  ≤0.1℃/year or 0.05%/year


Nota:
1: Con el protocolo HART, la carga máxima es: (potencia V - 12 V) /0.025A (corriente de salida). Cuando el riel está instalado, la carga máxima es: (potencia V - 10 V) /0.025A (corriente de salida).
2: Con el protocolo HART, la fuente de alimentación es de 12 ... 30 VCC. Cuando el riel está instalado, la fuente de alimentación es de 10 ... 30 VCC.
3: Con protocolo HART, sin protección contra rayos.
4: Con protocolo HART o instalación en carril, grupo anti-pulso: ± 3 000V.

Transmisor de temperatura pt100 de selección de tipo

Model Code Note
GTM   Smart temperature transmitter
Input signal(note 1)       A  Pt100
 RT  Pt1000
 RC Cu50
 K  K-type thermocouple
 S  S-type thermocouple
 R  R-type thermocouple
B B-type thermocouple
N N-type thermocouple
E E-type thermocouple
J J-type thermocouple
T T-type thermocouple
Output signal A 4-20 mA(two-wire)
H(note 2)  HART(two-wire 4-20mA)
 Configuration method   A  Slide switch
 P  Slide switch+PC programming
 Range   A(note 3)  Factory default settings
 X  User specified code (limited to 15 ranges)
 Installation   A  Top installation (screw fixation)
 D  Rail installation (35mm DIN rail)
 Annex   A  Standard
 B  With calibration report

Nota:
1: Al seleccionar múltiples señales de entrada (es decir, entrada universal), se recomienda equipar un programador de PC para el ajuste de rango.
2: El protocolo HART solo se aplica a productos montados en la parte superior.
3: El rango debe confirmar el rango de temperatura específico para que se pueda configurar en la fábrica.

Embalaje del transmisor de temperatura pt100

Transmisor de temperatura montado en cabezal de salida de 4-20 mA de entrada universal GTM102

Voz del transmisor de temperatura pt100 del cliente



Información de la empresa transmisor de temperatura pt100

¿COMO ORDENAR? CONTÁCTENOS AHORA COMO A CONTINUACIÓN⇓


Enviar Consulta

Alerta de productos

Suscríbase a sus palabras clave interesadas. Enviaremos libremente los productos más recientes y más populares a su bandeja de entrada. No se pierda ninguna información comercial.